 <Product Code="1" HighPic="https://images.icecat.biz/img/gallery/37264574_6004510202.jpg" HighPicHeight="345" HighPicSize="32615" HighPicWidth="560" ID="37264569" LowPic="https://images.icecat.biz/img/gallery_lows/37264574_6004510202.jpg" LowPicHeight="123" LowPicSize="5911" LowPicWidth="200" Name="RS160" IntName="RS160" LocalName="" Pic500x500="https://images.icecat.biz/img/gallery_mediums/37264574_6004510202.jpg" Pic500x500Height="308" Pic500x500Size="30721" Pic500x500Width="500" Prod_id="70TE0010UX" Quality="ICECAT" ReleaseDate="" ThumbPic="https://images.icecat.biz/img/gallery_thumbs/37264574_6004510202.jpg" ThumbPicSize="944" Title="Lenovo ThinkServer RS160 Server 0 GB Rack (1U) Intel® Xeon® E3 v6 E3-1230V6 3,5 GHz 8 GB DDR4-SDRAM" GeneratedIntTitle="Lenovo ThinkServer RS160 server" GeneratedLocalTitle="Lenovo ThinkServer RS160 Server 0 GB Rack (1U) Intel® Xeon® E3 v6 E3-1230V6 3,5 GHz 8 GB DDR4-SDRAM" BrandLocalTitle="">
  <CategoryFeatureGroup ID="10891" No="-80">
   <FeatureGroup ID="0">
    <Name ID="438000" langid="4" Value="Technische Details"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1051" No="100">
   <FeatureGroup ID="1">
    <Name ID="437973" langid="4" Value="Prozessor"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1049" No="90">
   <FeatureGroup ID="3">
    <Name ID="437975" langid="4" Value="Speicher"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2697" No="20">
   <FeatureGroup ID="5">
    <Name ID="437977" langid="4" Value="Bildschirm"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1053" No="50">
   <FeatureGroup ID="12">
    <Name ID="437983" langid="4" Value="Anschlüsse und Schnittstellen"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1055" No="-5">
   <FeatureGroup ID="14">
    <Name ID="5789172" langid="4" Value="Gewicht und Abmessungen"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1056" No="10">
   <FeatureGroup ID="27">
    <Name ID="5789178" langid="4" Value="Energie"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2698" No="5">
   <FeatureGroup ID="28">
    <Name ID="437998" langid="4" Value="Betriebsbedingungen"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1054" No="60">
   <FeatureGroup ID="35">
    <Name ID="438005" langid="4" Value="Netzwerk"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="8609" No="80">
   <FeatureGroup ID="47">
    <Name ID="5789131" langid="4" Value="Speichermedium"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="23800" No="-10">
   <FeatureGroup ID="67">
    <Name ID="5789156" langid="4" Value="Verpackungsdaten"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2695" No="3">
   <FeatureGroup ID="76">
    <Name ID="438043" langid="4" Value="Zertifikate"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="11644" No="15">
   <FeatureGroup ID="90">
    <Name ID="438055" langid="4" Value="Software"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="7714" No="-20">
   <FeatureGroup ID="116">
    <Name ID="4480855" langid="4" Value="Lieferumfang"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="4192" No="40">
   <FeatureGroup ID="124">
    <Name ID="438087" langid="4" Value="Erweiterungssteckplätze"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="53421" No="0">
   <FeatureGroup ID="143">
    <Name ID="1030928" langid="4" Value="Akku/Batterie"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="8611" No="-100">
   <FeatureGroup ID="146">
    <Name ID="5789159" langid="4" Value="Sonstige Funktionen"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="10890" No="30">
   <FeatureGroup ID="148">
    <Name ID="630460" langid="4" Value="Design"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="8610" No="70">
   <FeatureGroup ID="163">
    <Name ID="764416" langid="4" Value="Grafik"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="12136" No="13">
   <FeatureGroup ID="183">
    <Name ID="1210974" langid="4" Value="Prozessor Besonderheiten"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="10889" No="25">
   <FeatureGroup ID="184">
    <Name ID="1218768" langid="4" Value="Leistungen"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="20049" No="-70">
   <FeatureGroup ID="185">
    <Name ID="5789155" langid="4" Value="Merkmale"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="35829" No="0">
   <FeatureGroup ID="198">
    <Name ID="5789137" langid="4" Value="Logistikdaten"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="59907" No="0">
   <FeatureGroup ID="232">
    <Name ID="3584770" langid="4" Value="Lieferanteneigenschaften"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="76092" No="0">
   <FeatureGroup ID="279">
    <Name ID="7392241" langid="4" Value="Nachhaltigkeit"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="77982" No="0">
   <FeatureGroup ID="305">
    <Name ID="8858201" langid="4" Value="CO2-Fußabdruck"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <Category ID="156">
   <Name ID="436938" langid="4" Value="Server"/>
  </Category>
  <EANCode/>
  <FeatureLogo ID="1498" Feature_ID="2196" Value="Intel Xeon E3 v6" LogoPic="https://images.icecat.biz/img/feature_logo/1498-1295.png" Width="0" Height="0" Size="0">
   <Descriptions>
    <Description ID="6181" langid="4">Intel® Xeon® Prozessoren bieten Cloud Computing, Echtzeitanalysen, Verarbeitung für Ihr geschäftskritisches Unternehmen und Big Data-Einblicke. Verbessern Sie die Effizienz und Zuverlässigkeit Ihres Rechenzentrums, um jede Arbeitslast zu bewältigen.</Description>
   </Descriptions>
   <FeatureLogoFeatures>
    <FeatureLogoFeature ID="2196">
     <FeatureLogoValues>
      <FeatureLogoValue ID="6625">Intel Xeon E3 v6</FeatureLogoValue>
     </FeatureLogoValues>
    </FeatureLogoFeature>
   </FeatureLogoFeatures>
  </FeatureLogo>
  <ReleaseDate/>
  <EndOfLifeDate/>
  <ReasonsToBuy/>
  <BulletPoints/>
  <GeneratedBulletPoints>
   <GeneratedBulletPoint Value="Intel® Xeon® E3 v6 E3-1230V6 3,5 GHz" langid="4" No="1"/>
   <GeneratedBulletPoint Value="8 GB 2400 MHz DDR4-SDRAM 1 x 8" langid="4" No="2"/>
   <GeneratedBulletPoint Value="Rack (1U)" langid="4" No="3"/>
  </GeneratedBulletPoints>
  <ProductBundled/>
  <ProductDescription/>
  <ProductFamily ID="968" LowPic="" ThumbPic="">
   <Name ID="224058" langid="1" Value="ThinkServer"/>
   <Series ID="3249">
    <Name ID="1290773" langid="1" Value="RS"/>
   </Series>
  </ProductFamily>
  <ProductFeature Localized="0" ID="249773736" Local_ID="0" Value="Intel Xeon E3 v6" CategoryFeature_ID="11563" CategoryFeatureGroup_ID="1051" No="10100400" Optional="0" Presentation_Value="Intel® Xeon® E3 v6" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="Intel® Xeon® E3 v6">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2196">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449349" langid="4" Value="Prozessorfamilie"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="249773738" Local_ID="0" Value="E3-1230V6" CategoryFeature_ID="1239" CategoryFeatureGroup_ID="1051" No="100398" Optional="0" Presentation_Value="E3-1230V6" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="E3-1230V6">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="47">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449040" langid="4" Value="Prozessor"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250870889" Local_ID="0" Value="3.5" CategoryFeature_ID="73717" CategoryFeatureGroup_ID="1051" No="100396" Optional="0" Presentation_Value="3,5 GHz" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="3,5">
    <Measure ID="37">
     <Signs>
      <Sign ID="13070" langid="4"><![CDATA[GHz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="11379">
    <Measure ID="37" Sign="">
     <Signs>
      <Sign ID="13070" langid="4"><![CDATA[GHz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1036527" langid="4" Value="Prozessor-Taktfrequenz"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250870894" Local_ID="0" Value="3.9" CategoryFeature_ID="72626" CategoryFeatureGroup_ID="1051" No="100395" Optional="0" Presentation_Value="3,9 GHz" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="3,9">
    <Measure ID="37">
     <Signs>
      <Sign ID="13070" langid="4"><![CDATA[GHz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="7978">
    <Measure ID="37" Sign="">
     <Signs>
      <Sign ID="13070" langid="4"><![CDATA[GHz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="617141" langid="4" Value="Prozessor Boost-Frequenz"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869675" Local_ID="0" Value="4" CategoryFeature_ID="31274" CategoryFeatureGroup_ID="1051" No="100300" Optional="0" Presentation_Value="4" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="4">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="6089">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="445205" langid="4" Value="Anzahl Prozessorkerne"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869679" Local_ID="0" Value="8" CategoryFeature_ID="135262" CategoryFeatureGroup_ID="1051" No="100290" Optional="0" Presentation_Value="8 MB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="8">
    <Measure ID="19">
     <Signs>
      <Sign ID="6667" langid="4"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="10041">
    <Measure ID="19" Sign="">
     <Signs>
      <Sign ID="6667" langid="4"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1323603" langid="4" Value="Prozessor-Cache"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869683" Local_ID="0" Value="Intel C232" CategoryFeature_ID="47167" CategoryFeatureGroup_ID="1051" No="100250" Optional="0" Presentation_Value="Intel® C232" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Intel® C232">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="436">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="445673" langid="4" Value="Motherboard Chipsatz"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869694" Local_ID="0" Value="Dual" CategoryFeature_ID="135002" CategoryFeatureGroup_ID="1051" No="100240" Optional="1" Presentation_Value="Dual" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Dual">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21997">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1830205" langid="4" Value="Speicherkanäle, vom Prozessor unterstützt"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869676" Local_ID="0" Value="1" CategoryFeature_ID="1280" CategoryFeatureGroup_ID="1051" No="100090" Optional="0" Presentation_Value="1" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="596">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="445687" langid="4" Value="Anzahl installierter Prozessoren"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869708" Local_ID="0" Value="72" CategoryFeature_ID="135036" CategoryFeatureGroup_ID="1051" No="100010" Optional="1" Presentation_Value="72 W" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="72">
    <Measure ID="44">
     <Signs>
      <Sign ID="13076" langid="4"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="11778">
    <Measure ID="44" Sign="">
     <Signs>
      <Sign ID="13076" langid="4"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1090647" langid="4" Value="Thermal Design Power (TDP)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869678" Local_ID="0" Value="Smart Cache" CategoryFeature_ID="135210" CategoryFeatureGroup_ID="1051" No="100005" Optional="1" Presentation_Value="Smart Cache" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Smart Cache">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21716">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1766293" langid="4" Value="Prozessor Cache Typ"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869680" Local_ID="0" Value="8" CategoryFeature_ID="39190" CategoryFeatureGroup_ID="1051" No="100002" Optional="1" Presentation_Value="8 GT/s" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="8">
    <Measure ID="176">
     <Signs>
      <Sign ID="13138" langid="4"><![CDATA[GT/s]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="6975">
    <Measure ID="176" Sign="">
     <Signs>
      <Sign ID="13138" langid="4"><![CDATA[GT/s]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449529" langid="4" Value="Systembus-Rate"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869682" Local_ID="0" Value="LGA 1151 (Socket H4)" CategoryFeature_ID="39841" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="LGA 1151 (Socket H4)" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="LGA 1151 (Socket H4)">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2325">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449438" langid="4" Value="Prozessorsockel"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869684" Local_ID="0" Value="14" CategoryFeature_ID="134949" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="14 nm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="14">
    <Measure ID="98">
     <Signs>
      <Sign ID="13100" langid="4"><![CDATA[nm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1623">
    <Measure ID="98" Sign="">
     <Signs>
      <Sign ID="13100" langid="4"><![CDATA[nm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449839" langid="4" Value="Prozessor Lithografie"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250870896" Local_ID="0" Value="8" CategoryFeature_ID="134950" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="8" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="8">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7337">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1027770" langid="4" Value="Prozessor-Threads"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869685" Local_ID="0" Value="64-bit" CategoryFeature_ID="134951" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="64-Bit" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="64-Bit">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7975">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1323409" langid="4" Value="Prozessorbetriebsmodi"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869686" Local_ID="0" Value="Skylake" CategoryFeature_ID="134956" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Skylake" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="Skylake">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="18767">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1436337" langid="4" Value="Prozessor Codename"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869690" Local_ID="0" Value="64" CategoryFeature_ID="134998" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="64 GB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="64">
    <Measure ID="20">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="21987">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1830202" langid="4" Value="Maximaler interner Speicher, vom Prozessor unterstützt"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869691" Local_ID="0" Value="DDR3L-SDRAM,DDR4-SDRAM" CategoryFeature_ID="134999" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="DDR3L-SDRAM, DDR4-SDRAM" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="DDR3L-SDRAM, DDR4-SDRAM">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21994">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1830203" langid="4" Value="Speichertypen, vom Prozessor unterstützt"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869692" Local_ID="0" Value="1866,2400" CategoryFeature_ID="135000" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="1866,2400 MHz" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1866,2400">
    <Measure ID="18">
     <Signs>
      <Sign ID="13057" langid="4"><![CDATA[MHz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="21995">
    <Measure ID="18" Sign="">
     <Signs>
      <Sign ID="13057" langid="4"><![CDATA[MHz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1830204" langid="4" Value="Speichertaktraten, vom Prozessor unterstützt"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869693" Local_ID="0" Value="37.5" CategoryFeature_ID="135001" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="37,5 GB/s" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="37,5">
    <Measure ID="160">
     <Signs>
      <Sign ID="19041" langid="4"><![CDATA[GB/s]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="21996">
    <Measure ID="160" Sign="">
     <Signs>
      <Sign ID="19041" langid="4"><![CDATA[GB/s]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1748594" langid="4" Value="Durch den Prozessor (max) unterstützte Speicherbandbreite"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869695" Local_ID="0" Value="Y" CategoryFeature_ID="135019" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10196">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="880000" langid="4" Value="Execute Disable Bit"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869696" Local_ID="0" Value="Y" CategoryFeature_ID="135021" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10197">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1030033" langid="4" Value="Leerlauf Zustände"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869697" Local_ID="0" Value="Y" CategoryFeature_ID="135022" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10199">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1030034" langid="4" Value="Thermal-Überwachungstechnologien"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869698" Local_ID="0" Value="16" CategoryFeature_ID="135023" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="16" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="16">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="20905">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1694259" langid="4" Value="Maximale Anzahl der PCI-Express-Lanes"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869707" Local_ID="0" Value="N" CategoryFeature_ID="135032" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Nein" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Nein">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10283">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1030091" langid="4" Value="Eingebettete Optionen verfügbar"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869709" Local_ID="0" Value="8" CategoryFeature_ID="73754" CategoryFeatureGroup_ID="1049" No="10100200" Optional="0" Presentation_Value="8 GB" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="8">
    <Measure ID="20">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="11381">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1036619" langid="4" Value="Speicherkapazität"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869710" Local_ID="0" Value="DDR4-SDRAM" CategoryFeature_ID="4437" CategoryFeatureGroup_ID="1049" No="10100198" Optional="0" Presentation_Value="DDR4-SDRAM" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="DDR4-SDRAM">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="427">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449067" langid="4" Value="Interner Speichertyp"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869711" Local_ID="0" Value="64" CategoryFeature_ID="4705" CategoryFeatureGroup_ID="1049" No="99990" Optional="0" Presentation_Value="64 GB" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="64">
    <Measure ID="20">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1452">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449246" langid="4" Value="RAM-Speicher maximal"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869712" Local_ID="0" Value="4" CategoryFeature_ID="5722" CategoryFeatureGroup_ID="1049" No="100000" Optional="0" Presentation_Value="4" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="4">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="672">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449103" langid="4" Value="Speicherkartensteckplätze"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869713" Local_ID="0" Value="Y" CategoryFeature_ID="20420" CategoryFeatureGroup_ID="1049" No="100000" Optional="0" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1628">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="445845" langid="4" Value="ECC"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869714" Local_ID="0" Value="2400" CategoryFeature_ID="31277" CategoryFeatureGroup_ID="1049" No="100000" Optional="0" Presentation_Value="2400 MHz" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2400">
    <Measure ID="18">
     <Signs>
      <Sign ID="13057" langid="4"><![CDATA[MHz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="2900">
    <Measure ID="18" Sign="">
     <Signs>
      <Sign ID="13057" langid="4"><![CDATA[MHz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449448" langid="4" Value="Speichertaktfrequenz"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869715" Local_ID="0" Value="1 x 8" CategoryFeature_ID="73739" CategoryFeatureGroup_ID="1049" No="100000" Optional="0" Presentation_Value="1 x 8 GB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1 x 8">
    <Measure ID="20">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="11380">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1036575" langid="4" Value="Speicherlayout"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869727" Local_ID="0" Value="0" CategoryFeature_ID="18867" CategoryFeatureGroup_ID="8609" No="213001" Optional="0" Presentation_Value="0 GB" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="0">
    <Measure ID="20">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="3318">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449474" langid="4" Value="Gesamtspeicherkapazität"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869730" Local_ID="0" Value="Y" CategoryFeature_ID="41696" CategoryFeatureGroup_ID="8609" No="100820" Optional="0" Presentation_Value="Ja" Translated="1" Mandatory="1" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7335">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1323345" langid="4" Value="RAID-Unterstützung"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869758" Local_ID="0" Value="N" CategoryFeature_ID="5723" CategoryFeatureGroup_ID="8609" No="100000" Optional="0" Presentation_Value="Nein" Translated="1" Mandatory="1" Searchable="0">
   <LocalValue Value="Nein">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1120">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449288" langid="4" Value="Optisches Laufwerk - Typ"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869728" Local_ID="0" Value="0" CategoryFeature_ID="18868" CategoryFeatureGroup_ID="8609" No="100951" Optional="0" Presentation_Value="0" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="0">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3319">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5148649" langid="4" Value="Anzahl der installierten HDDs"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869729" Local_ID="0" Value="Serial ATA,Serial Attached SCSI (SAS)" CategoryFeature_ID="4431" CategoryFeatureGroup_ID="8609" No="100940" Optional="0" Presentation_Value="SATA, Serial Attached SCSI (SAS)" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="SATA, Serial Attached SCSI (SAS)">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="982">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5148645" langid="4" Value="HDD Schnittstelle"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869735" Local_ID="0" Value="Y" CategoryFeature_ID="64539" CategoryFeatureGroup_ID="8610" No="100200" Optional="0" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="9997">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1029886" langid="4" Value="Eingebaute Grafikadapter"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869736" Local_ID="0" Value="Aspeed AST2400" CategoryFeature_ID="134996" CategoryFeatureGroup_ID="8610" No="100195" Optional="0" Presentation_Value="Aspeed AST2400" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="Aspeed AST2400">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="9016">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="757355" langid="4" Value="Eingebautes Grafikkartenmodell"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869739" Local_ID="0" Value="Y" CategoryFeature_ID="41697" CategoryFeatureGroup_ID="1054" No="100000" Optional="0" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1347">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="445794" langid="4" Value="Ethernet/LAN"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869740" Local_ID="0" Value="10/100/1000Base-T(X)" CategoryFeature_ID="56945" CategoryFeatureGroup_ID="1054" No="100000" Optional="0" Presentation_Value="10/100/1000Base-T(X)" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10/100/1000Base-T(X)">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="747">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449112" langid="4" Value="Verkabelungstechnologie"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869741" Local_ID="0" Value="Gigabit Ethernet" CategoryFeature_ID="58780" CategoryFeatureGroup_ID="1054" No="100000" Optional="0" Presentation_Value="Gigabit Ethernet" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Gigabit Ethernet">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7484">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1027885" langid="4" Value="Ethernet Schnittstellen Typ"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869746" Local_ID="0" Value="3" CategoryFeature_ID="16225" CategoryFeatureGroup_ID="1053" No="101000" Optional="0" Presentation_Value="3" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="3">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2312">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449325" langid="4" Value="Anzahl Ethernet-LAN-Anschlüsse (RJ-45)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869743" Local_ID="0" Value="2" CategoryFeature_ID="17114" CategoryFeatureGroup_ID="1053" No="100500" Optional="0" Presentation_Value="2" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2308">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449424" langid="4" Value="Anzahl USB 2.0 Anschlüsse"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869744" Local_ID="0" Value="4" CategoryFeature_ID="138415" CategoryFeatureGroup_ID="1053" No="100490" Optional="0" Presentation_Value="4" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="4">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="22701">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1791611" langid="4" Value="USB 3.2 Gen 1 (3.1 Gen 1) Anzahl der Anschlüsse vom Typ A"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869745" Local_ID="0" Value="1" CategoryFeature_ID="16223" CategoryFeatureGroup_ID="1053" No="100000" Optional="0" Presentation_Value="1" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2323">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449437" langid="4" Value="Anzahl VGA (D-Sub) Anschlüsse"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869747" Local_ID="0" Value="1" CategoryFeature_ID="17113" CategoryFeatureGroup_ID="1053" No="100000" Optional="0" Presentation_Value="1" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1337">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449335" langid="4" Value="Anzahl serielle Anschlüsse"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869757" Local_ID="0" Value="Rack (1U)" CategoryFeature_ID="1235" CategoryFeatureGroup_ID="10890" No="10113007" Optional="0" Presentation_Value="Rack (1U)" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="Rack (1U)">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="734">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449109" langid="4" Value="Gehäusetyp"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869687" Local_ID="0" Value="UEFI" CategoryFeature_ID="62967" CategoryFeatureGroup_ID="10889" No="100000" Optional="0" Presentation_Value="UEFI" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="UEFI">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1829">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="448305" langid="4" Value="BIOS-Typ"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869688" Local_ID="0" Value="Y" CategoryFeature_ID="64541" CategoryFeatureGroup_ID="10889" No="100000" Optional="0" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3574">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449184" langid="4" Value="Trusted Platform Module (TPM)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869689" Local_ID="0" Value="2.0" CategoryFeature_ID="65769" CategoryFeatureGroup_ID="10889" No="100000" Optional="0" Presentation_Value="2.0" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2.0">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10318">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1323619" langid="4" Value="Trusted Platform Module (TPM) Version"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869681" Local_ID="0" Value="N" CategoryFeature_ID="20423" CategoryFeatureGroup_ID="11644" No="100090" Optional="0" Presentation_Value="Nein" Translated="1" Mandatory="1" Searchable="0">
   <LocalValue Value="Nein">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3233">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449472" langid="4" Value="Installiertes Betriebssystem"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250871110" Local_ID="0" Value="Microsoft Windows 10; Microsoft Windows Server 2012 R2 and 2016; Red Hat Enterprise Linux (RHEL) Server 7; SUSE Linux Enterprise Server (SLES) 11 and 12; VMware vSphere (ESXi) 6.0 and 6.5." CategoryFeature_ID="1289" CategoryFeatureGroup_ID="11644" No="100085" Optional="0" Presentation_Value="Microsoft Windows 10; Microsoft Windows Server 2012 R2 and 2016; Red Hat Enterprise Linux (RHEL) Server 7; SUSE Linux Enterprise Server (SLES) 11 and 12; VMware vSphere (ESXi) 6.0 and 6.5." Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="Microsoft Windows 10; Microsoft Windows Server 2012 R2 and 2016; Red Hat Enterprise Linux (RHEL) Server 7; SUSE Linux Enterprise Server (SLES) 11 and 12; VMware vSphere (ESXi) 6.0 and 6.5.">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2507">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449442" langid="4" Value="Kompatible Betriebssysteme"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869700" Local_ID="0" Value="Y" CategoryFeature_ID="105685" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10195">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1030032" langid="4" Value="Verbesserte Intel SpeedStep Technologie"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869701" Local_ID="0" Value="N" CategoryFeature_ID="105688" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Nein" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Nein">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10111">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234213" langid="4" Value="Intel® Wireless-Display (Intel® WiDi)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869702" Local_ID="0" Value="Y" CategoryFeature_ID="131546" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="18653">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234190" langid="4" Value="Intel® Virtualisierungstechnik für direkte I/O (VT-d)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869703" Local_ID="0" Value="Y" CategoryFeature_ID="134961" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="9672">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234201" langid="4" Value="Intel® Hyper-Threading-Technik (Intel® HT Technology)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869704" Local_ID="0" Value="2.0" CategoryFeature_ID="134965" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="2.0" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2.0">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="9733">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234183" langid="4" Value="Intel® Turbo-Boost-Technologie"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869705" Local_ID="0" Value="N" CategoryFeature_ID="134967" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Nein" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Nein">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10108">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234149" langid="4" Value="Intel® Quick-Sync-Video-Technik"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869706" Local_ID="0" Value="N" CategoryFeature_ID="134968" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Nein" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Nein">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10109">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="874669" langid="4" Value="Intel® InTru™ 3D Technologie"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869716" Local_ID="0" Value="N" CategoryFeature_ID="134969" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Nein" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Nein">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10113">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234199" langid="4" Value="Intel® Clear Video HD Technology für (Intel® CVT HD)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869717" Local_ID="0" Value="Y" CategoryFeature_ID="134970" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10187">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234203" langid="4" Value="Intel® Insider™"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869718" Local_ID="0" Value="Y" CategoryFeature_ID="134975" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10194">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234197" langid="4" Value="Intel® AES New Instructions (Intel® AES-NI)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869719" Local_ID="0" Value="Y" CategoryFeature_ID="134979" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10200">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234179" langid="4" Value="Intel® Trusted-Execution-Technik"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869720" Local_ID="0" Value="Y" CategoryFeature_ID="134980" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10276">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234121" langid="4" Value="Intel® Enhanced Halt State"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869721" Local_ID="0" Value="Y" CategoryFeature_ID="134981" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10282">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234192" langid="4" Value="Intel® VT-x mit Extended Page Tables (EPT)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869722" Local_ID="0" Value="Y" CategoryFeature_ID="134983" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="14804">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234208" langid="4" Value="Intel® Sicherer Schlüssel"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869723" Local_ID="0" Value="Y" CategoryFeature_ID="134984" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="14803">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234180" langid="4" Value="Intel® TSX-NI"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869724" Local_ID="0" Value="N" CategoryFeature_ID="134993" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Nein" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Nein">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21539">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234112" langid="4" Value="Intel® Clear Video Technologie"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869725" Local_ID="0" Value="Y" CategoryFeature_ID="134994" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21556">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234175" langid="4" Value="Intel® Software Guard Extensions (Intel® SGX)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869726" Local_ID="0" Value="N" CategoryFeature_ID="134995" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Nein" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Nein">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10277">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234200" langid="4" Value="Intel® Clear Video Technology für Mobile Internet Devices (Intel® CVT for MID)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869733" Local_ID="0" Value="Y" CategoryFeature_ID="135037" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="15741">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234103" langid="4" Value="Intel® 64"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869734" Local_ID="0" Value="Y" CategoryFeature_ID="135110" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21759">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234188" langid="4" Value="Intel® Virtualization Technologie (VT-X)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869748" Local_ID="0" Value="10 - 35" CategoryFeature_ID="4441" CategoryFeatureGroup_ID="2698" No="100045" Optional="0" Presentation_Value="10 - 35 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10 - 35">
    <Measure ID="65">
     <Signs>
      <Sign ID="13083" langid="4"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1112">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="13083" langid="4"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449282" langid="4" Value="Betriebstemperatur"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869749" Local_ID="0" Value="-40 - 60" CategoryFeature_ID="1777" CategoryFeatureGroup_ID="2698" No="100044" Optional="0" Presentation_Value="-40 - 60 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="-40 - 60">
    <Measure ID="65">
     <Signs>
      <Sign ID="13083" langid="4"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="757">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="13083" langid="4"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449114" langid="4" Value="Temperaturbereich bei Lagerung"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869750" Local_ID="0" Value="8 - 80" CategoryFeature_ID="1277" CategoryFeatureGroup_ID="2698" No="100035" Optional="0" Presentation_Value="8 - 80%" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="8 - 80">
    <Measure ID="64">
     <Signs>
      <Sign ID="2748" langid="4"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="703">
    <Measure ID="64" Sign="">
     <Signs>
      <Sign ID="2748" langid="4"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449105" langid="4" Value="Relative Luftfeuchtigkeit in Betrieb"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869751" Local_ID="0" Value="8 - 80" CategoryFeature_ID="12224" CategoryFeatureGroup_ID="2698" No="100033" Optional="0" Presentation_Value="8 - 80%" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="8 - 80">
    <Measure ID="64">
     <Signs>
      <Sign ID="2748" langid="4"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1383">
    <Measure ID="64" Sign="">
     <Signs>
      <Sign ID="2748" langid="4"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449342" langid="4" Value="Luftfeuchtigkeit bei Lagerung"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869752" Local_ID="0" Value="0 - 3048" CategoryFeature_ID="17300" CategoryFeatureGroup_ID="2698" No="100005" Optional="0" Presentation_Value="0 - 3048 m" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="0 - 3048">
    <Measure ID="54">
     <Signs>
      <Sign ID="13080" langid="4"><![CDATA[m]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="667">
    <Measure ID="54" Sign="">
     <Signs>
      <Sign ID="13080" langid="4"><![CDATA[m]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449102" langid="4" Value="Höhe bei Betrieb"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869754" Local_ID="0" Value="439" CategoryFeature_ID="6245" CategoryFeatureGroup_ID="1055" No="100040" Optional="0" Presentation_Value="439 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="439">
    <Measure ID="24">
     <Signs>
      <Sign ID="13060" langid="4"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1649">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="13060" langid="4"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449371" langid="4" Value="Breite"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869755" Local_ID="0" Value="411" CategoryFeature_ID="6241" CategoryFeatureGroup_ID="1055" No="100000" Optional="0" Presentation_Value="411 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="411">
    <Measure ID="24">
     <Signs>
      <Sign ID="13060" langid="4"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1650">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="13060" langid="4"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449372" langid="4" Value="Tiefe"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869756" Local_ID="0" Value="43" CategoryFeature_ID="6244" CategoryFeatureGroup_ID="1055" No="100000" Optional="0" Presentation_Value="43 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="43">
    <Measure ID="24">
     <Signs>
      <Sign ID="13060" langid="4"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1464">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="13060" langid="4"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449354" langid="4" Value="Höhe"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="250869699" Local_ID="0" Value="N" CategoryFeature_ID="94034" CategoryFeatureGroup_ID="8611" No="100020" Optional="1" Presentation_Value="Nein" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Nein">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="8782">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="738328" langid="4" Value="Eingebautes Display"/>
   </Feature>
  </ProductFeature>
  <ProductGallery>
   <ProductPicture IsMain="Y" LowPic="https://images.icecat.biz/img/gallery_lows/37264574_6004510202.jpg" LowPicHeight="123" LowPicWidth="200" LowSize="5911" No="1" Original="https://images.icecat.biz/img/gallery_raw/37264574_6004510202.png" OriginalSize="23107" Pic="https://images.icecat.biz/img/gallery/37264574_6004510202.jpg" Pic500x500="https://images.icecat.biz/img/gallery_mediums/37264574_6004510202.jpg" Pic500x500Height="308" Pic500x500Size="30721" Pic500x500Width="500" PicHeight="345" PicWidth="560" ProductPicture_ID="21674633" Size="32615" ThumbPic="https://images.icecat.biz/img/gallery_thumbs/37264574_6004510202.jpg" ThumbSize="944" Type="ProductImage" UpdatedDate="2024-03-14 19:05:00"/>
   <ProductPicture LowPic="" LowPicHeight="0" LowPicWidth="0" LowSize="0" No="999" Original="" OriginalSize="0" Pic="https://images.icecat.biz/img/feature_logo/1498-1295.png" Pic500x500="" Pic500x500Height="0" Pic500x500Size="0" Pic500x500Width="0" PicHeight="0" PicWidth="0" ProductPicture_ID="4309949491" Size="0" ThumbPic="https://images.icecat.biz/img/feature_logo_thumbs/1498-1295.png" ThumbSize="0" Type="FeatureLogo" UpdatedDate="" langid="4"/>
  </ProductGallery>
  <ProductMultimediaObject>
   <MultimediaObject ContentType="application/pdf" Date="2018-07-07 10:32:59" Description="Generated PDF" KeepAsURL="0" MultimediaObject_ID="0" Type="leaflet" UUID="00000000-0000-0000-0000-000000000000" langid="4" Height="0" PreviewHeight="0" PreviewSize="0" PreviewUrl="" PreviewWidth="0" Size="0" URL="https://icecat.biz/rest/product-pdf?productId=37264569&amp;lang=de" Width="0"/>
  </ProductMultimediaObject>
  <ProductRelated/>
  <SummaryDescription>
   <ShortSummaryDescription langid="4">Lenovo ThinkServer RS160, 3,5 GHz, E3-1230V6, 8 GB, DDR4-SDRAM, 0 GB, Rack (1U)</ShortSummaryDescription>
   <LongSummaryDescription langid="4">Lenovo ThinkServer RS160. Prozessorfamilie: Intel® Xeon® E3 v6, Prozessor-Taktfrequenz: 3,5 GHz, Prozessor: E3-1230V6. Speicherkapazität: 8 GB, Interner Speichertyp: DDR4-SDRAM, Speicherlayout: 1 x 8 GB. Gesamtspeicherkapazität: 0 GB, HDD Schnittstelle: SATA, Serial Attached SCSI (SAS). Ethernet/LAN, Verkabelungstechnologie: 10/100/1000Base-T(X). Gehäusetyp: Rack (1U)</LongSummaryDescription>
  </SummaryDescription>